NETEC Resource Library

Human Factors Risk Analyses of a Doffing Protocol for Ebola-Level Personal Protective Equipment: Mapping Errors to Contamination

Elemento

Click for External Resource*


Click to read full article*


*The link above may share a zip file (.zip) hosted on repository.netecweb.org. Zip files will download automatically.
*All other links are external and will open in a new window. If you click an external link, you are leaving the NETEC site, and we do not maintain, review, or endorse these materials. See our terms of use.


Item Type

Publicación

Terms of Use

By accessing these materials you are agreeing to our terms of use, which may be found here: Terms of Use.

Was this resource helpful?


Título

Human Factors Risk Analyses of a Doffing Protocol for Ebola-Level Personal Protective Equipment: Mapping Errors to Contamination

Descripción

Doffing protocols for personal protective equipment (PPE) are critical for keeping healthcare workers (HCWs) safe during care of patients with Ebola virus disease.

Fuente

Joel M Mumma, Francis T Durso, Ashley N Ferguson, Christina L Gipson, Lisa Casanova, Kimberly Erukunuakpor, Colleen S Kraft, Victoria L Walsh, Craig Zimring, Jennifer DuBose, Jesse T Jacob.

Fecha

2018-02-17

Citación

Joel M Mumma, Francis T Durso, Ashley N Ferguson, Christina L Gipson, Lisa Casanova, Kimberly Erukunuakpor, Colleen S Kraft, Victoria L Walsh, Craig Zimring, Jennifer DuBose, Jesse T Jacob, Centers for Disease Control and Prevention Epicenters Program, Division of Healthcare Quality Promotion; Human Factors Risk Analyses of a Doffing Protocol for Ebola-Level Personal Protective Equipment: Mapping Errors to Contamination, Clinical Infectious Diseases, Volume 66, Issue 6, 5 March 2018, Pages 950–958, https://doi.org/10.1093/cid/cix957

Resumen

Abstract

Background

Doffing protocols for personal protective equipment (PPE) are critical for keeping healthcare workers (HCWs) safe during care of patients with Ebola virus disease. We assessed the relationship between errors and self-contamination during doffing.

Methods

Eleven HCWs experienced with doffing Ebola-level PPE participated in simulations in which HCWs donned PPE marked with surrogate viruses (ɸ6 and MS2), completed a clinical task, and were assessed for contamination after doffing. Simulations were video recorded, and a failure modes and effects analysis and fault tree analyses were performed to identify errors during doffing, quantify their risk (risk index), and predict contamination data.

Results

Fifty-one types of errors were identified, many having the potential to spread contamination. Hand hygiene and removing the powered air purifying respirator (PAPR) hood had the highest total risk indexes (111 and 70, respectively) and number of types of errors (9 and 13, respectively). ɸ6 was detected on 10% of scrubs and the fault tree predicted a 10.4% contamination rate, likely occurring when the PAPR hood inadvertently contacted scrubs during removal. MS2 was detected on 10% of hands, 20% of scrubs, and 70% of inner gloves and the predicted rates were 7.3%, 19.4%, 73.4%, respectively. Fault trees for MS2 and ɸ6 contamination suggested similar pathways.

Conclusions

Ebola-level PPE can both protect and put HCWs at risk for self-contamination throughout the doffing process, even among experienced HCWs doffing with a trained observer. Human factors methodologies can identify error-prone steps, delineate the relationship between errors and self-contamination, and suggest remediation strategies.

Accesibilidad

Read with OUP subscription.

Collection