NETEC Resource Library

Detection of infectious influenza virus in cough aerosols generated in a simulated patient examination room

Contenu

Click for External Resource*


Click to read full article*


*The link above may share a zip file (.zip) hosted on repository.netecweb.org. Zip files will download automatically.
*All other links are external and will open in a new window. If you click an external link, you are leaving the NETEC site, and we do not maintain, review, or endorse these materials. See our terms of use.


Item Type

Publication

Terms of Use

By accessing these materials you are agreeing to our terms of use, which may be found here: Terms of Use.

Was this resource helpful?


Titre

Detection of infectious influenza virus in cough aerosols generated in a simulated patient examination room

Sujet

Description

The potential for aerosol transmission of infectious influenza virus (ie, in healthcare facilities) is controversial. We constructed a simulated patient examination room that contained coughing and breathing manikins to determine whether coughed influenza was infectious and assessed the effectiveness of an N95 respirator and surgical mask in blocking transmission.

Date

2012-06

Citer ce document

Noti, John D., William G. Lindsley, Francoise M. Blachere, Gang Cao, Michael L. Kashon, Robert E. Thewlis, Cynthia M. McMillen, William P. King, Jonathan V. Szalajda, and Donald H. Beezhold. 2012. "Detection of Infectious Influenza Virus in Cough Aerosols Generated in a Simulated Patient Examination Room." Clinical Infectious Diseases 54 (11):1569-77.

Résumé

Abstract

BACKGROUND:

The potential for aerosol transmission of infectious influenza virus (ie, in healthcare facilities) is controversial. We constructed a simulated patient examination room that contained coughing and breathing manikins to determine whether coughed influenza was infectious and assessed the effectiveness of an N95 respirator and surgical mask in blocking transmission.

METHODS:

National Institute for Occupational Safety and Health aerosol samplers collected size-fractionated aerosols for 60 minutes at the mouth of the breathing manikin, beside the mouth, and at 3 other locations in the room. Total recovered virus was quantitated by quantitative polymerase chain reaction and infectivity was determined by the viral plaque assay and an enhanced infectivity assay.

RESULTS:

Infectious influenza was recovered in all aerosol fractions (5.0% in >4 μm aerodynamic diameter, 75.5% in 1-4 μm, and 19.5% in <1 μm; n = 5). Tightly sealing a mask to the face blocked entry of 94.5% of total virus and 94.8% of infectious virus (n = 3). A tightly sealed respirator blocked 99.8% of total virus and 99.6% of infectious virus (n = 3). A poorly fitted respirator blocked 64.5% of total virus and 66.5% of infectious virus (n = 3). A mask documented to be loosely fitting by a PortaCount fit tester, to simulate how masks are worn by healthcare workers, blocked entry of 68.5% of total virus and 56.6% of infectious virus (n = 2).

CONCLUSIONS:

These results support a role for aerosol transmission and represent the first reported laboratory study of the efficacy of masks and respirators in blocking inhalation of influenza in aerosols. The results indicate that a poorly fitted respirator performs no better than a loosely fitting mask.

Accessibilité

Free on Oxford Academic and PubMed Central

Collection

Related Resource Topic Exhibits